Braz. dent. sci ; 24(4): 1-9, 2021. tab, ilus, graf
Article in English | LILACS, BBO | ID: biblio-1337615

ABSTRACT

Objective: The objective of this study was to characterize and correlate the absorption spectra of three photoinitiators [camphorquinone (CQ), diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) and phenylbis (2,4,6-trimethylbenzoyl)-phosphine oxide (BAPO)], using second or third-generation light curing units (LCU), and to evaluate the degree of conversion and the physical properties of an experimental resin adhesive. Material and methods: Second-generation (Radii-cal® and Emitter D®) and third-generation (Valo® Cordless and Bluephase N®) LCU were assessed regarding spectrum and irradiance rate of emitted light. Also, the photoinitiators (CQ, TPO and BAPO) were characterized by a light absorption spectrum assessed by UV-Vis spectroscopy, degree of conversion and yellowing effect. Statistical analyzes considered two-way ANOVA and post-hoc Tukey test. Results: BAPO presented higher reactivity compared to TPO. Regarding degree of conversion of the photoinitiators activated by different light-curing units, the Emitter D® device promoted a high degree of conversion. BAPO presented the highest yellowing effect values. Conclusions: The emission and absorption characteristics of the photoinitiators were different. The polymerization reaction activated by the second-generation light-curing unit was reduced when using an experimental resin with photoinitiator TPO, and the third-generation light-curing unit showed a higher polymerization potential regardless of the photoinitiator. (AU)


Objetivo: Caracterizar e correlacionar os espectros de absorção de três fotoiniciadores [canforoquinona (CQ), difenil 2,4,6-trimetilbenzil óxido de fosfina (TPO) e óxido de di (2,4,6-trimetilbenzil) difenil fosfina (BAPO)], com unidades de fotoativação (LCU) de segunda ou terceira geração, e avaliar o grau de conversão e as propriedades físicas de um adesivo experimental. Material e métodos: LCU de segunda geração (Radii-cal® e Emitter D®) e terceira geração (Valo® Cordless e Bluephase N®) foram avaliadas quanto ao espectro e taxa de irradiância da luz emitida. Além disso, os fotoiniciadores (CQ, TPO e BAPO) foram caracterizados por um espectro de absorção de luz avaliado por espectroscopia UV-Vis, avaliado o grau de conversão dos adesivos e efeito de amarelamento. A análise estatística empregada foi ANOVA duas vias e teste post-hoc de Tukey. Resultados: BAPO apresentou maior reatividade comparado ao TPO. Em relação ao grau de conversão dos fotoiniciadores ativados por diferentes aparelhos fotopolimerizadores, o dispositivo Emitter D® promoveu um alto grau de conversão. BAPO apresentou os maiores valores de efeito de amarelamento. Conclusões: As características de emissão e absorção dos fotoiniciadores foram diferentes. A reação de polimerização ativada pelas unidades de fotopolimerização de segunda geração foi reduzida com o uso de uma resina experimental com fotoiniciador TPO. As unidades de fotopolimerização de terceira geração apresentaram maior potencial de polimerização independentemente do fotoiniciador. (AU)


Subject(s)
Light-Curing of Dental Adhesives , Curing Lights, Dental , Photoinitiators, Dental
2.
Dental press j. orthod. (Impr.) ; 18(6): 112-116, Nov.-Dec. 2013. ilus, tab
Article in English | LILACS | ID: lil-697739

ABSTRACT

OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the low possibility of contamination during the process. METHODS: One hundred and twenty specimens were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used while in group 2 a led light-curing unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used while in subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. RESULTS: The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p > 0.05) and the ARI (p > 0.05) between the subgroups. CONCLUSION: The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requirements for bonding orthodontic accessories, and that the time for bonding was reduced to half, being necessary only one light exposure.


OBJETIVO: desenvolver uma nova ponteira para ser acoplada aos aparelhos fotopolimerizadores utilizados para colagem de braquetes e acessórios ortodônticos, e testar sua da efetividade em ensaio mecânico in vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos de refração e reflexão de luz. Apresenta como principal vantagem o menor tempo clínico durante o procedimento de colagem, reduzindo a possibilidade de contaminação durante o processo. MÉTODOS: por meio de ensaio de resistência ao cisalhamento e determinação do índice remanescente de adesivo (IRA), testou-se a ponteira desenvolvida em 120 corpos de prova. A amostra foi dividia em dois grupos. No grupo 1, foi utilizado aparelho fotopolimerizador de fonte de luz halógena e, no grupo 2, fonte de LED. Cada grupo foi subdividido. Nos subgrupos H1 e L1, utilizou-se a ponteira convencional. Nos subgrupos H2 e L2 a colagem foi feita utilizando a ponteira desenvolvida para a polimerização do material de colagem. RESULTADOS: os valores dos testes de cisalhamento e IRA para os subgrupos foram comparados entre si. Os resultados mostraram que não houve diferença estatisticamente significativa para o ensaio de resistência ao cisalhamento (p > 0,05) nem para o IRA (p > 0,05) entre os subgrupos. CONCLUSÃO: os testes de ensaio mecânico, assim como a análise do IRA, mostraram que a nova ponteira desenvolvida cumpriu os requisitos necessários à colagem dos acessórios ortodônticos, e que o tempo de colagem foi reduzido pela metade, sendo necessária uma só incidência.


Subject(s)
Humans , Curing Lights, Dental , Dental Bonding/instrumentation , Light-Curing of Dental Adhesives/instrumentation , Orthodontic Brackets , Adhesiveness , Curing Lights, Dental/classification , Dental Stress Analysis/instrumentation , Equipment Design , Equipment Contamination/prevention & control , Materials Testing , Optical Fibers , Resin Cements/chemistry , Resin Cements/radiation effects , Shear Strength , Stress, Mechanical , Surface Properties , Time Factors
3.
Araraquara; s.n; 2013. 105 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867806

ABSTRACT

Objetivo: Avaliamos in vitro as variações da sensação de cor (∆E) e suas correlações após o clareamento de dentes submetidos à colagem e remoção de brackets ortodônticos, considerando: 1) o tempo de condicionamento ácido (15, 30 e 60 segundos); 2) os sistemas adesivos (TransbondTMXT, Opal Seal/Bond e TransbondTM Plus SEP) e 3) o momento em que o clareamento foi realizado em relação à presença de brackets (antes, durante ou depois), bem como o índice de adesivo remanescente (IAR) após descolagem dos brackets. Materiais e Métodos: Este trabalho foi subdividido em três artigos para abordar cada um dos objetivos propostos. A amostra foi composta de 270 pré-molares humanos, distribuídos aleatoriamente em 9 grupos: controle negativo (reprodutibilidade); controle positivo (apenas clareamento dentário); e 7 grupos experimentais. A determinação da cor dentária foi obtida pelo sistema CIELab, a partir de dados do espectrofotômetro, em avaliações da cor prévia ao clareamento e em 1, 15 e 30 dias após. Para verificar se existia diferença entre os grupos foi aplicada ANOVA a um fator, uma vez que o tamanho da amostra de cada grupo foi de n=30 (p < 0,05). E quando ANOVA indicou diferença, para identificar quais grupos diferiam entre si, foi aplicado o teste de comparações múltiplas de Tukey para variâncias homogêneas, identificadas pelo teste de Levene (p < 0,05). Resultados: O ∆E desde o préclareamento até 15 e 30 dias após foi estatisticamente diferente entre: o controle e o grupo com condicionamento ácido durando 15 segundos (p<0,05); o controle e os grupos colados com sistema adesivo TransbondTM XT e TransbondTM Plus SEP; assim como entre o grupo colado com Opal Seal/Bond e TransbondTM Plus SEP. Quanto ao momento em o clareamento foi realizado, apenas a variável IAR apresentou diferença estatisticamente significante nos valores médios, entre os três grupos experimentais (p < 0,05). Quanto às correlações, a variação de cor verificada 1 dia após o clareamento estava fortemente correlacionada com a de 15 dias após, assim como 15 com 30 dias após clareamento. Conclusões: O tempo de condicionamento ácido e os sistemas adesivos para colagem de brackets influenciaram o ∆E após clareamento. O momento em que o clareamento foi realizado não influenciou o ∆E, mas afetou o IAR, modificando a interface de fratura do adesivo durante a descolagem de brackets. E, a variação de cor obtida após 1 dia de clareamento estava correlacionada com a verificada após 15 e 30 dias


Objective: To evaluate in vitro the degree of color changes (∆E) and their correlations after bleaching tooth surfaces subjected to orthodontic brackets bonding and debonding, regarding: 1) the etching time (15, 30 and 60 seconds); 2) the adhesive system (TransbondTM XT, Opal Seal/Bond and TransbondTM Plus SEP); 3) the time point in which bleaching was performed (before, during and after bonding of brackets) and the adhesive remnant index (IAR) after bracket debonbing. Materials and Methods: This study was divided in three articles to address each of the proposed objectives. The sample consisted of 270 extracted premolars randomly divided in 9 groups: negative control (reproducibility); positive control (tooth bleaching only); and 7 experimental groups. The tooth color was determined by the CIELab system using the spectrophotometer data, in evaluations prior to bleaching and 1, 15 and 30 days after bleaching. To test whether there was difference between the groups one-way ANOVA was used, since the sample size of each group was n=30 (p<0,05). When ANOVA indicated a difference, in order to identify which groups differed from each other, we applied the multiple comparison test of Tukey for homogeneity of variances, identified by the Levene test (p < 0,05). Results: The ∆E from pre-bleaching up to 15 and 30 days after bleaching was statistically different between: control and etching time group of 15 seconds (p < 0,05); control and groups bonded withTransbondTM XT and TransbondTM Plus SEP bonding systems; as well as the group bonded with Opal Seal/Bond and TransbondTM Plus SEP. Regarding the time when the bleaching was performed, only the variable IAR presented statistically significant difference in the mean values among the three groups (p < 0,05). As for correlations, the color variation observed 1 day after bleaching was strongly correlated with 15 days after bleaching, as well as 15 to 30 days after bleaching. Conclusion: The etching time and the bonding systems influenced the ∆E after bleaching. The time point in which bleaching was performed did not influence the ∆E, but affected the IAR, modifying the interface of adhesive fracture during bracket debonding. In addition, the ∆E obtained 1 day after bleaching was correlated with those observed 15 and 30 days after bleaching


Subject(s)
Humans , Orthodontic Brackets , Color , Dental Cements , Tooth Bleaching , Light-Curing of Dental Adhesives , Orthodontics , Acid Etching, Dental , Bicuspid , In Vitro Techniques , Analysis of Variance , Dentin-Bonding Agents
4.
Araraquara; s.n; 2013. 82 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867774

ABSTRACT

IIntrodução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas pela broca multilaminada em baixa rotação. Conclusão: O TPSEP mostrou ser o modo de condicionamento de esmalte mais adequado para colagem de bráquetes; a não fotopolimerização do primer reduziu as resistências das colagens ao cisalhamento dos bráquetes metálicos, mas não as dos bráquetes cerâmicos; o tempo de execução do procedimento e o aspecto final da superfície do esmalte demonstraram que a broca multilaminada em baixa deve ser o método de escolha para remoção dos resíduos de adesivo


Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated that multi-blade carbide burr may be the method of choice to remove residual adhesive


Subject(s)
Microscopy, Electron, Scanning , Finite Element Analysis , Orthodontic Brackets , Dental Cements , Light-Curing of Dental Adhesives , Dental Enamel , Shear Strength , Bicuspid , Molar
5.
ROBRAC ; 21(58)jul.-set. 2012. tab
Article in Portuguese | LILACS | ID: lil-676056

ABSTRACT

O objetivo desse estudo foi analisar a efetividade de sistemas adesivos convencionais e autocondicionantes, e de diferentes métodos de fotoativação para redução da microinfiltração marginal. Foram utilizados 48 dentes incisivos bovinos nesse estudo. Os dentes foram divididos em quatro grupos de 12 amostras de acordo com o tipo de adesivo ou método de fotoativação utilizado: Grupo 1- Sistema adesivo de passos fotoativadas por luz halógena com intensidade de 700 mW/cm2 Grupo 2 - Sistema adesivo de dois passos fotoativados pelo LED com intensidade de 470 mW/cm2; Grupo 3 - sistema adesivo autocondicionante fotoativados por luz halógena; Grupo 4 - Sistema adesivo autocondicionante fotoativados por LED. Uma resina composta nanoparticulada foi utilizada para restaurar todas as cavidades. Em seguida, os grupos foram submetidos ao tratamento de ciclagem térmica e foram colocados por 24 horas em solução de azul de metileno. A microinfiltração foi avaliada de acordo com o grau de penetração do corante na interface dente-restauração. Para análise estatística, foi utilizado o teste não paramétrico de Kruskal Wallis complementado pelo teste de Mann-Whitney, no nível de 5% de significância. O grupo 1 apresentou estatisticamente menores índices de microinfiltração marginal que o grupo 2 na parece oclusal (p<0.05) e os grupos 1 e 4 apresentaram menores graus de microinfiltração marginal que o grupo 2 na parede cervical(p<0.05). A aplicação do sistema adesivo de dois passos associado a polimerização com luz halógena promoveram os menores graus de microinfiltração marginal.


The aim of this research was to analyze the effectiveness of conventional and self-etching bonding systems and different curing methods for reduction of marginal microleakage. 48 bovine incisor teeth were used in this study. The teeth were divided into four groups of 12 samples according to the type of adhesive system or curing method used: Group 1- Two-step bonding system photoactivated by halogen light with intensity of 700 mW/cm2; Group 2- Two-step bonding system photoactivated by LED with 470 mW/ cm2 of intensity; Group 3 - Self etch bonding system photoactivated by halogen light; Group 4- Self etch bonding system photoactivated by LED. A nanofilled composite resin was used to restore all the cavities. Then the groups were subjected to thermal cycling treatment and were placed for 24 hours in a methylene blue solution. The microleakage was assessed according to the degree ofpenetration of the colorant in tooth-restoration interface. For statistical analysis, the non-parametric Kruskal Wallis test complemented by Mann-Whitney were used with 5 % level of significance. The Group 1 showed lower marginal microleakage than Group 2 on occlusal wall (p<0.05). Adittionally, appears and the groups 1 and 4 had smaller degrees of marginal microleakage that the cervical wall 2 Group (p<0.05). The application of two-step bonding system associated with the polymerization by halogen light promoted the lowest degrees of marginal microleakage.

6.
Arq. odontol ; 47(1): 4-8, Jan.-Mar. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-725225

ABSTRACT

Objetivo: Avaliar o efeito da incorporação de um sal de iodônio em cimentos resinosos experimentais em sua eficiência como agentes de fixação de braquetes ao esmalte. Materiais e Métodos: Uma mistura comonomérica de dimetacrilatos foi carregada com 35% de partículas de vidro. Três agentes foram obtidos pelo acréscimo do hexafluorfosfato de ditoliliodônio nas concentrações 0 (controle), 1 (R1) ou 2mol% (R2). Braquetes de aço inoxidável foram colados na face vestibular de incisivos bovinos, sendo fotoativados com fonte de luz de lâmpada halógena com irradiância de 400mW/cm2. Os cimentos foram fotoativados com duas exposições de luz (nas faces cervical e incisal do braquete), sendo testados dois tempos de fotoativação: 5s ou 20s. O teste de cisalhamento foi realizado 10min após a colagem. Os valores de resistência de união foram calculados em MPa e os dados submetidos a ANOVA de 2 critérios e teste de Student-Newman-Keuls (5%). O Índice de Adesivo Remanescente (IAR) foi avaliado sob aumento e submetido ao teste de Kruskal- Wallis (5%). Resultados: Para o tempo 20s houve diferenças entre todos os materiais: R1 > R2 > controle, enquanto para o tempo 5s R1 e R2 foram similares entre si, e superiores ao controle. A resistência de união para o tempo 5s foi inferior a o tempo 20s para os grupos controle e R1, e similar para R2. A redução dos valores na comparação entre os tempos 20s e 5s foi de 55% (controle), 45% (R1) e 15% (R2). Não houve diferenças significativas entre os grupos nos escores IAR. Conclusão: O desenvolvimento de agentes de fixação contendo sais de iodônio pode possibilitar a colagem de braquetes utilizando tempos reduzidos de fotoativação.(AU)


Aim: To evaluate the impact of adding an iodonium salt to experimental resin cements on their efficiency as agents for bonding brackets to enamel. Materials and Methods: A dimethacrylate co-monomer blend was loaded with 35% glass particles. Three agents were obtained by adding concentrations of 0 (control), 1 (R1) or 2mol% (R2) of ditolyliodonium hexafluorophosphate. Stainless steel brackets were bonded to the buccal faces of bovine incisors; photoactivation was carried out using a quartz-tungsten-halogen unit with 400mW/ cm2-irradiance. The cements were photoactivated using two exposures (on the cervical and incisal faces of the bracket), testing two photoactivation times: 5s or 20s. The shear test was carried out 10min after bonding. Bond strength values were calculated in MPa, and the data were submitted to a two-way ANOVA and Student-Newman-Keuls' test (5%). The Adhesive Remnant Index (ARI) was evaluated under magnification and submitted to the Kruskal-Wallis test (5%). Results: For the time 20s, significant differences among all materials were observed: R1 > R2 > control, whereas for the time 5s, R1 and R2 were similar, showing higher bond strength than the control. The bond strength for the time 5s was lower than for the time 20s for control and R1, but similar for R2. The reduction in bond strength values comparing the times 20s and 5s was 55% (control), 45% (R1) and 15% (R2). Conclusion: The development of bonding agents containing iodonium salts may produce a favorable atmosphere for bonding brackets using reduced photoactivation times.(AU)


Subject(s)
Orthodontic Brackets , Resin Cements , Light-Curing of Dental Adhesives , Dental Materials